    Brand Name : YOKG
    Model Number : PR8NM
    Certification : CE, KEMA
    Price : Negotiable
    Payment Terms : L/C, D/P, T/T
    Supply Ability : 100000pcs per Month
    Delivery Time : 15days or Depends on ordering QTYS
    • Product Details
    • Company Profile

    16-100A Electromagnetic Circuit Breaker RCBO 6kA 230V 400V

    Electromagnetic leakage protector PR8NM 6kA RCBO 16-100A circuit breaker


    The Electromagnetic Circuit Breaker Have Following Advatages:

    1. Control electric circuits

    2. Protect people against indirect contacts and additional protection against direct contacts

    3. Protect installations against fire hazard due to insulation faults

    4. Residual current circuit breakers are used in housing, tertiary sector and industry

    5. Support 35mm Din-rail installation


    Tripping sensitivity:

    ♦ 30 mA--additional protection against direct contact

    ♦ 100mA--co-ordinated with the earth system according to the formula In<50/R, to provide protection against indirect contacts

    ♦ 300mA, protection against indirect contacts, as well we fire hazard


    Specifications:

    Poles2P,4P
    Electrical Specification
    Rated current (A) In16-100A
    Rated working voltage (V) Ue2P:230, 4P:400
    Rated insulated voltage (V) Ui500
    Impulse withstand voltage (kV) Uimp6
    Rated short circuit breaking capacity (kA) Inc/I△n6
    Rated residual current (mA) I△n10,30,100,300
    Rated residual making and breaking capacity (A) I△m1000
    residual current working typeAC,AC+S, A, A+S
    residual current protection typeElectromagnetic
    Dielectric test voltage(kV)2.5
    Service life Mechanical Standard value4000
    (O-C) Electrical Standard value2000
    Control And indication
    Shunt release (SHT)NONE
    Undervoltage release (UVT)NONE
    Auxiliary contact(AUX)NONE
    Contact position indicatorNONE
    Fault indicationDEFAULT
    Connection And Installation
    Ambient temperature (with daily average ≤35℃)-5℃ ~ +40℃
    Protection degree All sidesIP40
    connection terminalIP20
    Wire(m㎡)35
    Busbar (m㎡)35
    MountingCable/Busbar
    Reference temperature for setting of thermal element30
    Pollution degree2
    Storage temperature(℃)-25℃ ~ +70℃
    ConnectionTop
    Dimensions(mm) a(2P/4P)36/72
    b(2P/4P)84/84
    c(2P/4P)79.5/79.5

    Selection:

    ♦ Detectable wave form

    ♦ AC type

    ♦ A type

    RCCB for which tripping ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowing rising, Symbol



    Tripping time:

    ♦ Instantaneous: Instantaneous tripping can be ensured (without time-delay)

    ♦ Short time delay : Any tripping can be ensured at least 10ms

    ♦ Selective : Total discrimination with a nonselective RCD placed downstream are ensured.


    Connection Diagram:



    The diagram of distribution line:




    Quality 16-100A Electromagnetic Circuit Breaker RCBO 6kA 230V 400V for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: YueQing ZEYI Electrical Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)