    Brand Name : YOKG
    Model Number : SC18
    Certification : CE,TUV,CB
    Price : Negotiable
    Payment Terms : L/C, D/P, T/T
    Supply Ability : 100000pcs per Month
    Delivery Time : 15days or Depends on ordering QTYS
    • Product Details
    • Company Profile

    IEC60947 SC Series AC Electric Contactor SC18 32A 690V 3 Poles

    YOKG SC Series AC Electric Contactor 20A 690V 3poles Black Contactor


    Application:

    SC series AC contactors are mainly used for AC 50Hz / 60Hz.rated voltage up to 660V and rated current up to 95A for remote switch, breaking and frequent starting, controlling the AC motor. Moreover, the contactor can act as the time-delay contactor, reversible contactor, star-delta starter by the accessories addition such as addition of modular auxiliary contact set. Air time delay head, mechanical interlock mechanism, etc. Moreover,it could act as the electromagnetic starter by the direct plug of the thermal relay.

    This series contactor complies with GB 14048, IEC60947-4-1


    Main parameters and Technical Performance:

    TypeSC18
    Rated heating current (A)32
    Rated insulation voltage (V)690
    Rated impact withstand voltage (KV)6
    Rated making capacity10le
    Rated breaking capacity8le
    Poles3
    Auxiliary contactNO/NC
    Short-time withstand current(A)10S144
    Rated working current(A)380VAC-318
    AC-47.7
    660VAC-312
    AC-43.8
    AC-3 capacity of phase 3
    squirrel-cage motor (AC-3) KW
    220V4
    380V7.5
    660V10
    Operation frequency (times/h)Electrical lifeAC-31200
    AC-4300
    Mechanical life3600
    Electrical life (10000/times)AC-3100
    AC-420
    Mechanical life (10000/times)1000
    Equipped fuse typeRT16-32
    Rated control supply voltage Us(V)50/60Hz12~480
    Operation rangePull-in(85%~110%)Us +40℃
    Releasing(20%~75%)Us -5℃
    Ac coil average power(VA)Start70
    Keeping8
    Power efficiency classclass 3
    Thermal loss(W)2~3
    Actuation time(ms)Close12~25
    Break5~20
    Main circuit wiringflexible wire without cold
    pressing terminal (㎟)
    1 stick1.5~6
    2 sticks1.5~6
    flexible wire with cold
    pressing terminal (㎟)
    1 stick1~6
    2 sticks1~4
    Hard wire (㎟)1 stick1.5~6
    2 sticks1.5~6
    Fastening screw sizeM3.5
    Tightening fastening torque (N.m)0.8
    Control loop wiringflexible wire without cold
    pressing terminal (㎟)
    1 stick1~4
    2 sticks1~4
    flexible wire with cold
    pressing terminal (㎟)
    1 stick1~4
    2 sticks1~2.5
    Hard wire (㎟)1 stick1~4
    2 sticks1~4
    Fastening screw sizeM3.5
    Tightening fastening torque (N.m)0.8

    Model and Implication:

    Working and Installation Condition:

    Ambient air temperature: -5℃--+40℃ and average not more than +35℃ within 24 hours;

    Altitude: ≤ 2000m;

    Air condition: when the highest temperature is +40℃, the air relative humidity is not up to 50%, but the higher humidity is allowed at lower temperature. Like, 90% humidity at 20℃. The condensate dew should be considered when at lower temperature;

    Pollution degree: Class 3

    Installation category:III

    Protection degree: IP20

    Installation condition: the gradient angle between installation side and vertical side should not be more than ±5℃

    Impact and vibrattion: the contactor must be installed and operate under the circumstances of no obvious shaking, impact and vibration.


    Structure characteristic:

    It can be installed with auxiliary contacts block, time relay and current-limited contacts block, and thermal relay, then to be other derivative products;

    This series contactor has small volume, light weight, less power loss, long life and safe and reliability etc;

    The contactor can be equipped with 1NO auxiliary contact or 1NC auxiliary contact(less than 32A), and 1NO auxiliary contact+1NC auxiliary contact(more than 40A). In addition, it can be equipped with F4 auxiliary contactor block (2blocks or 4blocks);

    In addition to use screw to install, contactor can be tightened with the standard installing rail of 35mm (sc09~95) and the standard installing rail of 75mm(SC40~95)


    Installation dimension:

    A maxB maxC maxab
    47768734/3550/604.5